Configuring the Trap Table
Operational
For all ports except those noted below, this means that the link is up.
For SNA TPAD, this means that the XID exchange has been performed, and the
XID data received in the response frame matches the XID data conÞgured for the
TPAD subscriber. The link is ready to establish an X.25 connection with the
remote HPAD.
For SNA HPAD, this means that an XID or SNRM command frame has been
received for at least one of the link addresses conÞgured for the HPAD subscriber.
The link is ready to establish an X.25 connection with the remote TPAD.
Severity
Call Clr LCN = "n" cc = "n" dc = "n"
Self-explanatory.
Severity
Action
End of IPL
Self-explanatory.
Severity
PVC is Up
Self-explanatory.
Severity
PVC Reset
A Reset was sent on the PVC.
Severity
Received Reset LCN = "n", cc = "n" dc = "n"
A Reset was received on the designated LCN, with the cause code cc and
diagnostic code dc.
Severity
Received Reset Confirm
A Reset ConÞrmation was received.
Severity
3-10
Major (Level 2)
Informational (Level 4)
Depends on the cause. If necessary, contact your service
representative.
Informational (Level 4)
Informational (Level 4)
Informational (Level 4)
Informational (Level 4)
Informational (Level 4)