Chapter 2 Safety regulations

Protection Devices

Operate the system only if all safety- and protection devices are completely available and
functional. Check the protection devices for its function:
At first operation.
¥
At regular routine test.
¥
After exchange of security-relevant components and parts.
¥
If deficiencies occur during operation at the protection devices, stop the system immedia-
tely and remedy the deficiencies! Do not change or remove any protection devices. Do not
take the protection devices out of operation by any change.
Protection devices may only be removed when the system is stopped and safeguarded
against re-starting of the system (e.g. padlock at main switch, disconnect power plug from
power connection). If subcomponents are supplied, the protection devices have to be in-
stalled according to the regulations by the operator.
Connection to the customer's conveying system may evoke dangerous areas at the transi-
tions. Suitable safety measures have to be taken in this case.

Labeling station's cover

The fixed and screwed system covers protect the user against mechanical hazards.
*² Main switch
Fig. 2-3: Main switch with lock
Lock always the main switch:
During maintenance- and service works.
¥
If switching on the system may lead to a hazard
¥
*² Emergency-Stop Push Button
Fig. 2-4: Emergency-Stop Push
Version: 16.07.13
The main switch serves for switching the system on and off.
In position "0" it interrupts the power supply to the system
but however the supply in front of the switch can be ener-
gized.
The main switch can be locked in position "0" as a protec-
tion against a hazard by accidentally or unauthorized swit-
ching on of the system.
The emergency stop pushbutton serves for an immediate stop-
ping of the complete labeling system. It should only be used in
emergency situations.
The emergency stop pushbutton is locked after actuation and
has to be locked manually before restarting (consider the infor-
mation at the button).
Button
Page 22 of 77
32708885 Geset 100
*²Only if system has the appropriate features.