Chapter 9 Maintenance

Semi-annual servicing (after appr. 1000 hours of operation)

Requirements
Labeler is without electrical power.
¥
No transportation of products.
¥
Required equipment
Vacuum cleaner
¥
Instruction
Please arrange the semi-annual maintenance as follows
Step
1
2
3

Annual servicing (after appr. 2000 hours of operation)

Requirements
Labeler is without electrical power.
¥
No transportation of products.
¥
Required equipment
Bearing grease Proline, Pro 672U (92100772, food compliant)
¥
*Product recommendation. Can be obtained from the Bluhm Weber Group with the eight-character article number.
Instruction
Please arrange the yearly servicing as follows.
Step
1
2
Version: 16.07.13
Procedure
Replace all *²air filter elements of *²switch cabinet, *² protective cabi-
nets....
Clean the system cover's outside and the *²protective cabinet's inside
with a vacuum cleaner.
Do not use air pressure from the shop air supply as it is often not dry
(oil-/ water residues). If humidity gets in the electronics, it may lead to
damages!
Check moving or rotating machine parts for bearing play. Possible
repairs have to be arranged professionally.
Procedure
Examine ...
Base conveyor
¥
*²Top conveyor
¥
Conveying belts
¥
... for correct belt tension. Possible repairs have to be arranged im-
mediately and professionally. (Instruction s. pages 67 and 69).
Clean at all *²linear strokes the guiding- and piston rods and grease
them slightly.
Page 62 of 77
32708885 Geset 100