Routing - Siemens SIMATIC NET SCALANCE SC-600 Configuration Manual

Industrial ethernet security web based management (wbm)
Hide thumbs Also See for SIMATIC NET SCALANCE SC-600:
Table of Contents

Advertisement

Configuring with Web Based Management
4.3 "Information" menu
Power Loss State
To be able to monitor the power loss of the connection the function fiber monitoring
must be enabled for the optical port of the connection partner.
• disabled
Fiber monitoring is disabled.
• ok
The value for the power loss of the optical link is within the defined limits.
• maint. req.
Check the link.
A warning is signaled.
• maint. dem.
The link needs to be checked.
An alarm is signaled and the fault LED is lit.
• idle
The port has no connection to another port with fiber monitoring enabled.
If no diagnostics information is received from the optical port of the connection
partner for 5 cycles, the fiber monitoring connection is assumed to be interrupted. A
cycle lasts 5 seconds.
Power Loss [dB]
Shows the current value of the power loss. The value can have a tolerance of +/- 3 dB.
If there is no connection (link down), Fiber Monitoring is disabled or the partner port
does not support Fiber Monitoring, "-" is displayed.
4.3.10

Routing

Introduction
This page shows the routes currently being used.
94
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03