Configuring with Web Based Management
4.7 "Security" menu
• Primary Server
Using the options in the drop-down list, specify whether or not this server is the
primary server. You can select one of the options "yes" or "no".
• Test
With this button, you can test whether or not the specified RADIUS server is available.
The test is performed once and not repeated cyclically.
• Test Result
Shows whether or not the RADIUS server is available:
– Not reachable
– Reachable, key not accepted
– Reachable, key accepted
Procedure
Entering a new server
1. Click the "Create" button. A new entry is generated in the table.
The following default values are entered in the table:
– RADIUS Server Address: 0.0.0.0
– Server Port: 1812
– Max. Retrans.: 3
– Primary server: No
2. In the relevant row, enter the following data in the input boxes:
– RADIUS Server Address
– Server Port
– Shared Secret
– Shared Secret Conf
– Max. Retrans.: 3
– Primary server: No
3. If necessary check the reachability of the RADIUS server.
4. Click the "Set Values" button.
Repeat this procedure for every server you want to enter.
296
The IP address is not reachable.
The IP address is reachable, the RADIUS server is, however, not running.
The IP address is reachable, the RADIUS server does not, however accept the
shared secret.
The IP address is reachable, the RADIUS server accepts the specified shared
secret.