Siemens SIMATIC NET SCALANCE SC-600 Configuration Manual page 121

Industrial ethernet security web based management (wbm)
Hide thumbs Also See for SIMATIC NET SCALANCE SC-600:
Table of Contents

Advertisement

• Min. TLS version
Specify the minimum TLS version to be used.
• Default Login Page
Specify the login page with which the WBM starts by default.
– Firewall
– Configuration
• SMTP Client
Enable or disable the SMTP client. You can configure other settings in "System >
SMTP Client".
• Syslog Client
Enable or disable the Syslog client. You can configure other settings in "System >
Syslog Client".
• DCP Server
Specify whether the device can be accessed with DCP (Discovery and Configuration
Protocol):
– "-" (disabled)
– Read/Write
– Read Only
• Time
Select the setting from the drop-down list. The following settings are possible:
– Manual
– SIMATIC Time
– SNTP Client
– NTP Client
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
Logging into the WBM page for dynamic firewall.
Logging into the WBM.
DCP is disabled. Device parameters can neither be read nor modified.
With DCP, device parameters can be both read and modified.
With DCP, device parameters can be read but cannot be modified.
The system time is set manually. You can configure other settings in "System >
System Time > Manual Setting".
The system time is set via a SIMATIC time source. You can configure other
settings in "System > System Time > SIMATIC Time Client".
The system time is set via an SNTP server. You can configure other settings in
"System > System Time > SNTP Client".
The system time is set via an NTP server. You can configure other settings in
"System > System Time > NTP Client".
Configuring with Web Based Management
4.4 "System" menu
121