• Link-layer address (LL)
The link-layer address is based on the MAC address. The value is regenerated each
time the factory settings are restored.
• Configuration mode
Select the mode from the drop-down list. The following modes are possible:
– Automatic Save
– Trial
Procedure
1. To use the required function, select the corresponding check box.
2. Select the options you require from the drop-down lists.
3. Click the "Set Values" button.
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
Automatic backup mode. Approximately 1 minute after the last parameter change
or before you restart the device, the configuration is automatically saved.
In addition to this, the following message appears in the display area "Changes will
be saved automatically in x seconds. Click 'Write Startup Config' to save the
changes immediately."
Note
Interrupting the save
Saving starts only after the timer in the message has elapsed. How long saving
takes depends on the device.
During the save, the message "Saving configuration data in progress. Please do
not switch off the device." is displayed.
• Do not switch off the device immediately after the timer has elapsed.
Trial mode. In Trial mode, although changes are adopted, they are not saved in the
configuration file (startup configuration).
To save changes in the configuration file, use the "Write startup config" button.
The display area also shows the message "Trial Mode Active – Press the "Write
Startup Config" button to make your settings persistent" as soon as there are
unsaved modifications. This message can be seen on every WBM page until the
changes made have either been saved or the device has been restarted.