Siemens SIMATIC NET SCALANCE SC-600 Configuration Manual page 219

Industrial ethernet security web based management (wbm)
Hide thumbs Also See for SIMATIC NET SCALANCE SC-600:
Table of Contents

Advertisement

• Status Device Name
– Discovered: The set device name is used.
– Configured: The device was assigned a new device name.
• Status IP Address
– Discovered/IP: The device uses a static IPv4 address.
– Discovered/DHCP: The device has obtained the IPv4 address from a DHCP server.
– Configured: The device was assigned a new IPv4 address.
• Timeout[s]
Specify the time for flashing. When the time elapses, flashing stops.
• Flash
Makes the port LEDs of the selected device flash.
Configuration procedure
1. Select the TIA interface.
2. To show all devices that can be reached via the TIA interface, click the "Browse"
button.
3. Adapt the desired properties.
4. Click the "Set Values" button.
The status of the modified properties changes to "Configured".
5. To ensure that the properties were applied correctly, click the "Browse" button again.
The status of the modified properties changes to "Discovered".
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
Configuring with Web Based Management
4.4 "System" menu
219