Siemens SCALANCE X-300M PoE Compact Operating Instructions

Industrial ethernet switches
Hide thumbs Also See for SCALANCE X-300M PoE:

Advertisement

Quick Links

SCALANCE X-300M PoE
SIMATIC NET
Industrial Ethernet switches
SCALANCE X-300M PoE
Compact Operating Instructions
05/2016
A5E02630810-09
___________________
Introduction
___________________
Safety notes
___________________
Description
___________________
Assembling
___________________
Connecting
___________________
Technical data
___________________
Dimension drawings
___________________
Approvals
___________________
Appendix
1
2
3
4
5
6
7
8
A

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SCALANCE X-300M PoE

  • Page 1 ___________________ SCALANCE X-300M PoE Introduction ___________________ Safety notes ___________________ SIMATIC NET Description ___________________ Assembling Industrial Ethernet switches SCALANCE X-300M PoE ___________________ Connecting ___________________ Technical data Compact Operating Instructions ___________________ Dimension drawings ___________________ Approvals ___________________ Appendix 05/2016 A5E02630810-09...
  • Page 2: Legal Information

    Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    24 VDC signaling contact ....................... 33 Connecting the external 24 VDC power supply ..............34 Technical data ............................37 Construction, installation and environmental conditions ............37 Connectors and electrical data ....................39 SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 4 SCALANCE X-300 declaration of conformity ................. 53 Overview of the approvals ..................... 53 Mechanical stability in operation .................... 53 Appendix .............................. 55 The connector system M12/X coded according to IEC 61076-2-109 ........55 Index ..............................57 SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 5: Introduction

    Purpose of the Operating Instructions (compact) Based on the Operating Instructions (compact), you will be able to install and connect up the SCALANCE X-300M PoE correctly. The configuration and the integration of the device in a network are not described in these instructions.
  • Page 6 Security messages Note Siemens offers IT security mechanisms for its automation and drive product portfolio in order to support the safe operation of the plant/machine. Our products are also continuously developed further with regard to IT security. We therefore recommend that you regularly check for updates of our products and that you only use the latest versions.
  • Page 7: Type Designation

    Examples: "X-300" stands for non-modular devices with a compact housing, "XR-300" means all rack devices, "X-300M" means all modular devices etc. SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 8 Introduction 1.2 Type designation SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 9: Safety Notes

    Safety notices on the use of the device The following safety notices must be adhered to when setting up and operating the device and during all associated work such as installation, connecting up, replacing or opening the device. SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 10 Requirements for the cabinet/enclosure When used in hazardous environments corresponding to Class I, Division 2 or Class I, Zone 2, the device must be installed in a cabinet or a suitable enclosure. SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 11: Important Notes On Using The Device In Hazardous Areas

    This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or non- hazardous locations only. WARNING Restricted area of application This equipment is suitable for use in Class I, Zone 2, Group IIC or non-hazardous locations only. SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 12: Pelv

    The supply of the devices by PELV (Protective Extra Low Voltage) according to DIN VDE 0100-410 or IEC 60364-4-41 is permitted when the generated nominal voltage does not exceed the voltage limits 25 VAC or 60 VDC. SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 13: Description

    Module slots 10/100/1000 Mbps X308-2M PoE Components of the product The following parts ship with a SCALANCE X-300M PoE: ● Device with C-PLUG exchangeable medium ● 4-pin terminal block for the power supply ● 2-pin terminal block for the signaling contact ●...
  • Page 14: Power Over Ethernet (Poe)

    (type 1) for environment A , in other words power supply over Ethernet within a power supply system. For details of configuring and enabling PoE for individual ports, refer to the configuration manual SCALANCE X-300 / X-400 on the accompanying CD. SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 15: The Set / Select Button

    A. 2. Hold down the SELECT/SET button for 12 seconds. If you release the button before the 12 seconds have elapsed, the reset is canceled. SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 16: Led Display

    The device is operating in the role of redundancy manager. An interruption has been detected on the ring and the device has switched through. SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 17 A. Pressing the SELECT/SET button Status of the "DM" LED Display mode starting at display mode A Display mode A (default mode) Press once lit green Display mode B SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 18 For devices with power supply unit 24 to 48 VDC: Limit voltage = 17 VDC • For devices with a multiple range power supply unit 100 to 240 VAC / 60 to 250 VDC: • Limit voltage = 46.5 VDC or 80 VAC SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 19 (1000 Mbps, 100 Mbps, 10 Mbps) continues to be displayed. If there is a problem on the connection and autonegotiation is active, the port LED goes off. SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 20: C-Plug

    The first time it is started up, the replacement device has the same configuration as the previous device except for the MAC address set by the vendor. SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 21: Removing And Inserting The C-Plug (Compact Housing)

    In devices with a compact housing, the C-PLUG is located behind the sealing screw on the rear of the device. To remove the sealing screw, use a coin or a wide blade screwdriver. SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 22 3. The housing of the C-PLUG has a protruding ridge on the long side (position B). The slot has a groove at this position. Insert the C-PLUG correctly oriented into the slot. 4. Close the housing again with the sealing screw. SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 23: Assembling

    WARNING To comply with EC Directive 2014/34/EU (ATEX 114) or the conditions of IECEx, this enclosure or cabinet must meet the requirements of at least IP54 in compliance with EN 60529. SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 24: Suitable Cables For Temperatures Above 70 °C - Cable 50 °C - 70 °C (Atex)

    Provide suitable shade to protect the IE Switch X-300 against direct sunlight. This avoids unnecessary warming of the IE Switch X-300 and prevents premature aging of the IE Switch X-300 and the cabling. SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 25: Installing On An S7-300 Standard Rail

    (> 10 g). Under such conditions, the device can come out of the mounting and may cause injury. In such situations, install the device on an S7-300 standard rail. SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 26: Wall Mounting

    1. For wall mounting, use suitable mounting fittings for the wall (for example, for a concrete wall, four plugs 6 mm diameter and 30 mm long, 4 screws 3.5 mm diameter and 40 mm long). 2. Connect the electrical cable connecting cables. SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 27: Fitting And Removing Media Modules And Sfps

    You will find the Operating Instructions for both of these on the Cd that ships with the SCALANCE X-300. A printed version of the Operating Instructions (compact) for the SCALANCE MM900 also ships with the media modules. SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 28 Assembling 4.7 Fitting and removing media modules and SFPs SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 29: Connecting

    Remove the protective caps only immediately before you use the plug-in connection. Note Wire end ferrules Use crimp shapes with smooth surfaces, such as provided by square and trapeze shaped crimp cross sections. Crimp shapes with wave-shaped profile are unsuitable. SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 30 This is the case if you only operate devices with SELV (safety extra-low voltage). WARNING Before connecting up and commissioning the device, read the information in the section Safety notes (Page 9) SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 31: Notes On Commissioning

    Stripped length of the cable 8 - 10 mm Wire end ferrule according to DIN 46228 with plastic ferrule** 8 - 10 mm * AWG: American Wire Gauge ** See note "Wire end ferrules" SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 32: Grounding

    If the switch is mounted on a non-conductive base, you will need to use the grounding cable. The grounding cable is not supplied with the device. Connect the paint-free surface of the switch to the nearest grounding point using the grounding cable. SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 33: 24 Vdc Signaling Contact

    The signaling contact can be subjected to a maximum load of 100 mA (safety extra-low voltage SELV, 24 V DC). Table 5- 1 Pin assignment of the 24 VDC signaling contact Pin number Assignment Pin 1 Pin 2 SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 34: Connecting The External 24 Vdc Power Supply

    IE Switch X-300 alone. ● The power supply is connected over a high resistance with the enclosure to allow an ungrounded set up. The two power inputs are non-floating. SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 35 Terminal block assignment (4-pin) Table 5- 2 Pinout of the 24 V safety extra-low voltage (SELV) Pin number Assignment Labeling (example) Pin 1 L1+ (24 VDC) Pin 2 Pin 3 Pin 4 L2+ (24 VDC) SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 36 Connecting 5.6 Connecting the external 24 VDC power supply SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 37: Technical Data

    2000 m or above: -5 °C of the max. operating temperature 3000 m or above: -10 °C of the max. operating temperature See table: "Operating temperature depending on the media modules used" SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 38 The permitted operating temperature depends on how the mounting device was installed. The installation is horizontal if the device labeling is from left to right. With a vertical installation, the de- vice labeling is rotated through 90°. SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 39: Connectors And Electrical Data

    100 mA Table 6- 9 Plug-in terminal block for connectors of the power supply and signaling contact Power supply 1 x 4-pin male connector Signaling contact 1 x 2-pin male connector SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 40 Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 with 4-wire industrial twisted-pair cables, the wires are connected to pins 1, 2, 3 and 6. SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 41: Cable Lengths

    Permitted cable lengths (fiber-optic cable - Fast Ethernet or gigabit) The values correspond to those of the permitted MM900 media modules and SFP transceivers. Other properties Table 6- 15 Switching properties Max. number of learnable addresses 8000 Aging time 30 sec SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 42 At 100 Mbps At 1000 Mbps 148810 1488095 64 bytes 84459 844595 128 bytes 45290 452899 256 bytes 23496 234962 512 bytes 11973 119732 1024 bytes 9615 96154 1280 bytes 8127 81274 1518 bytes SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 43 • at 64 bytes frame length: Delay of approx. 10 microseconds (at 100 Mbps) • at 1500 bytes frame length: Delay of approx. 130 microseconds (at 100 Mbps) This means, the more IE Switches X-300 a frame runs through, the higher the frame delay. SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 44 Technical data 6.4 Other properties SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 45: Dimension Drawings

    Dimension drawings All dimensions in the drawings are in millimeters. Image 7-1 X308-2M PoE: Front view SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 46 Dimension drawings Image 7-2 X308-2M PoE: Side view SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 47 Dimension drawings Image 7-3 X308-2M PoE: Drilling template SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 48 Dimension drawings SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 49: Approvals

    Approvals for shipbuilding are not printed on the device type plate. Note Shipbuilding approval You will find shipbuilding approvals on the Internet on the pages of Siemens Industry Automation Customer Support under the following entry ID: 33118441 (http://support.automation.siemens.com/WW/view/en/33118441) "Entry list" tab > entry type "Certificates"...
  • Page 50 (http://support.automation.siemens.com/WW/view/en/27069465)", in "Further documentation". – "EMC Installation Guidelines" configuration manual ID = 60612658 (http://support.automation.siemens.com/WW/view/en/60612658) ● Working on the device To protect the device from electrostatic discharge, personnel must first discharge any electrostatic charge from their body before touching the device.
  • Page 51 Area". You will find this document • on the data medium that ships with some devices. • on the Internet pages of Siemens Industry Online Support (http://support.automation.siemens.com/WW/view/en). Enter the document identification number C234 as the search term. SIMATIC NET products meet the requirements of the EC directive:94/9/EC "Equipment and Protective Devices for Use in Potentially Explosive Atmospheres".
  • Page 52 ● ANSI/ISA 12.12.01-2007 ● CSA C22.2 No. 213-M1987 Approved for use in Cl. 1, Div. 2, GP A, B, C, D T4 Cl. 1, Zone 2, GP IIC T4 Report no. E240480 SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 53: Scalance X-300 Declaration Of Conformity

    For temperature information "T.." or the maximum ambient temperature "Ta:..", refer to the type plate. Note Shipbuilding approval You will find shipbuilding approvals on the Internet on the pages of Siemens Industry Automation Customer Support under the following entry ID: 33118441 (http://support.automation.siemens.com/WW/view/en/33118441) "Entry list"...
  • Page 54 Approvals 8.4 Mechanical stability in operation IEC 60068-2-27 (shock) ● Securing on a DIN rail 15 g, 11 ms duration, 6 shocks per axis SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 55: Appendix

    White / orange White / orange Orange Orange White / green White / green Green Blue White / brown White / blue Brown Green White / blue White / brown Blue Brown SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 56 Appendix A.1 The connector system M12/X coded according to IEC 61076-2-109 SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 57: Index

    Index Glossary, 6 Safety notices for installation, 23 general, 9 Use in hazardous areas, 9, 23, 29 when connecting up, 29 SIMATIC NET glossary, 6 System manual, 50 SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...
  • Page 58 Index SCALANCE X-300M PoE Compact Operating Instructions, 05/2016, A5E02630810-09...

Table of Contents