Siemens SIMATIC NET SCALANCE SC-600 Configuration Manual page 245

Industrial ethernet security web based management (wbm)
Hide thumbs Also See for SIMATIC NET SCALANCE SC-600:
Table of Contents

Advertisement

Description
Table 1 has the following columns:
• All Ports
Shows that the settings are valid for all ports.
• Setting
Select the setting from the drop-down list. If "No Change" is selected, the entry in
table 2 remains unchanged.
• Copy to Table
If you click the button, the setting is adopted for all ports of table 2.
Table 2 has the following columns:
• Port
Shows the available ports.
• Setting
Specify the LLDP functionality. The following options are available:
– Rx
– Tx
– Rx & Tx
– "-" (disabled)
Procedure
1. Select the LLDP functionality of the port from the "Setting" drop-down list.
2. Click the "Set Values" button.
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
This port can only receive LLDP frames.
This port can only send LLDP frames.
This port can receive and send LLDP frames.
This port can neither receive nor send LLDP frames.
Configuring with Web Based Management
4.5 "Layer 2" menu