Siemens SIMATIC NET SCALANCE SC-600 Configuration Manual page 190

Industrial ethernet security web based management (wbm)
Hide thumbs Also See for SIMATIC NET SCALANCE SC-600:
Table of Contents

Advertisement

Configuring with Web Based Management
4.4 "System" menu
Description
The page contains the following boxes:
• NTP client
When enabled, the device receives the system time from an NTP server.
• Secure NTP Client only
When enabled, the device receives the system time from a secure NTP server. The
setting applies to all server entries.
To use the secure NTP client, you configure the parameters for authentication (key
ID, hash algorithm, key).
• Current System Time
Shows the current date and current normal time received by the device. If you specify
a time zone, the time information is adapted accordingly.
• Last Synchronization Time
Shows when the last time-of-day synchronization took place.
• Last Synchronization Mechanism
Shows how the last time synchronization was performed. The following methods are
possible:
– Not set
– Manual
– SNTP
– NTP
– SIMATIC
– PTP
• Time Zone
Enter the time zone you are using in the format "+/- HH:MM". The time zone relates
to UTC standard world time.
The time in the "Current System Time" box is adapted accordingly.
190
The time was not set.
Manual time setting
Automatic time-of-day synchronization with SNTP
Automatic time-of-day synchronization with NTP
Automatic time-of-day synchronization using the SIMATIC time frame
Automatic time-of-day synchronization with PTP
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03