Upkeep and maintenance

5.3 Restoring the factory settings

5.3
Restoring the factory settings
NOTICE
Previous settings
If you reset, all the settings you have made will be overwritten by factory defaults.
NOTICE
Inadvertent reset
An inadvertent reset can cause disturbances and failures in a configured network with
further consequences.
With the reset button
When pressing the button, remember the information in the section "Reset button" in the
operating instructions.
Follow the steps below to reset the device parameters to the factory settings:
1. Turn off the power to the device.
2. Now press the Reset button and reconnect the power to the device while holding down
the button.
3. Hold down the button until the red fault LED (F) stops flashing after approximately 10
seconds and is permanently lit.
4. Now release the button and wait until the fault LED (F) goes off again.
5. The device then starts automatically with the factory settings.
Via the configuration
You will find detailed information on resetting the device parameters using the WBM and
CLI in the configuration manuals:
• Web Based Management, section "Restart"
• Command Line Interface, section "Reset and Defaults"
352
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03