Supported Function Rights - Siemens SIMATIC NET SCALANCE SC-600 Configuration Manual

Industrial ethernet security web based management (wbm)
Hide thumbs Also See for SIMATIC NET SCALANCE SC-600:
Table of Contents

Advertisement

Configuring with Web Based Management
4.3 "Information" menu
In the table "External User Accounts" a user is linked to a role. In this example the user
"Observer" is linked to the "user" role. The user is defined on a RADIUS server. The role
is defined locally on the device. When a RADIUS server authenticates a user, the
corresponding group however is unknown or does not exist, the device checks whether
or not there is an entry for the user in the table "External User Accounts". If an entry
exists, the user is logged in with the rights of the associated role. If the corresponding
group is known on the device, both tables are evaluated. The user is assigned the role
with the higher rights.
Note
The table "External User Accounts" is only evaluated if you have set "SiemensVSA" in
the RADIUS Authorization Mode.
With CLI you can access external user accounts.
The "Local User Accounts" and "External User Accounts" tables have the following
columns:
• Account
Shows the name of the local user.
• Role
Shows the role of the user. You can obtain more information on the function rights of
the role in "Information > Security > Roles".
4.3.15.2

Supported Function Rights

Note
The values displayed depend on the role of the logged-on user.
The page shows the function rights available locally on the device.