4.3.2.1. Multi-Turn Actuator With Output Drive Types B: Mount To Valve/Gearbox; Accessories For Assembly; Stem Protection Tube For Rising Valve Stem - AUMA SAEx 07.2 Manual

Multi-turn actuators
Hide thumbs Also See for SAEx 07.2:
Table of Contents

Advertisement

SAEx 07.2
SAEx 16.2 / SAREx 07.2
AUMA MATIC AMExC 01.1
Information

4.3.2.1. Multi-turn actuator with output drive types B: mount to valve/gearbox

4.4.

Accessories for assembly

4.4.1.

Stem protection tube for rising valve stem

SAREx 16.2
Spigot at valve flanges should be loose fit.
Figure 11: Mounting output drive types B
[1]
Multi-turn actuator
[2]
Valve/gearbox
[3]
Valve/gearbox shaft
1.
Check if mounting flanges fit together.
2.
Check, if output drive of multi-turn actuator [1] matches the output drive of
valve/gearbox or valve/gearbox valve shaft [2/3].
3.
Apply a small quantity of grease to the valve or gearbox stem [3].
4.
Fit multi-turn actuator [1].
Information: Ensure that the spigot fits uniformly in the recess and that the
mounting faces are in complete contact.
5.
Fasten multi-turn actuator with screws according to table.
Information: We recommend applying liquid thread sealing material to the
screws to avoid contact corrosion.
6.
Fasten screws crosswise to a torque according to table.
Table 5:
Tightening torques for screws
UNC threads
M threads
1/4"
M6
5/16"
M8
3/8"
M10
1/2"
M12
5/8"
M16
3/4"
M20
Option
Tightening torque ft-lb [Nm]
Strength class
8.8
A2-80
8 [11]
7 [10]
18 [25]
18 [24]
38 [51]
35 [48]
64 [87]
60 [82]
158 [214]
148 [200]
318 [431]
289 [392]
Assembly