SAEx 07.2
SAEx 16.2 / SAREx 07.2
AUMA MATIC AMExC 01.1
5.3.3.
Terminal compartment: close
5.4.
Accessories for electrical connection
5.4.1.
Controls mounted to wall bracket
Application
SAREx 16.2
Figure 24: Close terminal compartment
[1]
Cover
[2]
Screws for cover
[3]
O-ring
[4]
Blanking plugs
[5]
Cable gland (example)
[6]
Frame
1.
Clean sealing faces of cover [1] and frame [6].
2.
Preserve joint surfaces with an acid-free corrosion protection agent.
3.
Check whether O-ring [3] is in good condition, replace if damaged.
4.
Apply a thin film of non-acidic grease to the O-ring and insert it correctly.
Flameproof enclosure, danger of explosion!
Risk of death or serious injury.
Handle cover and housing parts with care.
Joint surfaces must not be damaged or soiled in any way.
Do not jam cover during fitting.
5.
Fit cover [1] and fasten screws [2] evenly crosswise.
The wall bracket allows separate mounting of controls and actuator.
When mounted in confined spaces.
If the actuator is subjected to high temperatures.
In case of heavy vibration of the valve.
Electrical connection