Reissued: 29-Jan-15
Model:
Sh-MF1
RTB Reissue
The areas in bold italics have been added or revised.
Subject:
Countermeasure to HC wristband model
From:
3rd Tech Service Sect., MFP/P Tech Service Dept.
Classification:
Note:
 This document is for the Sh-MF1/P1 HC wristband model.
 Wristband models are sold only in the U.S. market.
SYMPTOM
1. Cannot open the main paper tray.
2. Paper stuck at the Teflon Mylar.
3. Non-feed jam
POSSIBLE CAUSE
The shape of the 3-inch tray bottom plate is not optimal.
1.
The shape of the Teflon Mylar is not optimal.
2.
The spring lengthens over time as the machine is operated
3.
SOLUTION
1. Replace the tray bottom plate.
2. Replace the HC Teflon Mylar.
3. Replace the spring (included in #1) and change the setting of the "Paper thickness lever".
PART INFORMATION
1. 3inch tray bottom plate: M0529907
Note: P/N M0529907 is used on the wristband model only.
2. A set of the following 3 parts (for main tray): M0529911
-Teflon Mylar: 1 piece
-Tension springs: 2 pieces
-Paper thickness cover decal: 1 sheet
3. A set of 5 sheets of the cover decal: M0529912
4. A set of 2 tension springs: M0529908
See the Procedures below:
1. 3 inch tray bottom plate
2. HC Teflon Mylar (Refer to RTB: RM052081)
3. Paper thickness lever setting and attaching cover decal (Refer to RTB: M052082)
echnical
T
Troubleshooting
Mechanical
Paper path
Product Safety
ulletin
B
Date:
5-Dec-14
Prepared by:
Part information
Electrical
Transmit/receive
Other (
)
.
PAGE: 1/9
No.:
RM052083a
J.Kitagawa
Action required
Service manual revision
Retrofit information