6. Put ADF on the Scanner. Important: To prevent damage to the ADF cable, please
loosen the cable (yellow circle). Wipe off the oil dirt on the surface of the DF hinge
bottom part with alcohol and cloth to prevent dirt on the exposure glass.(Red circle)
7. Remove the scanner cover, push at the red arrow in the picture. 1 screw
8. Remove the screws on the left hand of the hinge holder. 2 screw
9. Remove the screw. 1 screw
10. Pull the left hinge holder as shown by the red arrow in the picture.
11. Re-assemble the new hinge holder in the reverse order of the steps above.