Ricoh Sh-MF1 Technical Bulletin page 127

Hide thumbs Also See for Sh-MF1:
Table of Contents

Advertisement

echnical
ulletin
T
B
PAGE: 3/6
Model:
Date:
No.:
Sh-MF1 (Only for Health Care Models)
1-Aug-14
RM052072
3. Remove the Mylar, making sure that none of the double-sided tape remains.
Front
Mylar
Base
4. Clean both surfaces well (inner/outer) using a towel with alcohol, and dry them well.
Area to clean
IMPORTANT
DO NOT touch rollers with alcohol-damp towel.

Advertisement