Ricoh Sh-MF1 Technical Bulletin page 8

Hide thumbs Also See for Sh-MF1:
Table of Contents

Advertisement

Reissued: 24-Jul-15
Model:
Sh-MF1
RTB Reissue
The items in bold italics have been corrected or added.
Subject:
Firmware Release Note: PCL
From:
3rd Tech Service Sect., MFP/Printer Tech Service Dept.
Classification:
This RTB has been issued to announce the firmware release information for the PCL.
Version
Program No.
1.07
1.06
1.05
1.04
1.03
1.02
1.01
Note: Definition of Availability of RFU via @Remote
"Available" The firmware can be updated via RFU or SD card.
"Not available": The firmware can only be updated via SD card.
Version
1.07
Symptom corrected:
1.
If a PCL5 job is printed under certain conditions related to the font header
information when using host printing, PCL default fonts are used.
(GFPR#RE14100009)
1.06
Symptom corrected:
1.
If the glyph data of TrueType fonts includes hinting information that is on the
edge of the frame, an SC899 error might occur. (GFPR#RC14030010)
1.05
Symptom corrected:
1. Additional condition that caused "SC899 caused by the printing of specific kinds
of TrueType fonts in PCL jobs" to still occur after the release of v1.04.
(GFPR#RE11070014, GFPR#RC12050012, GFPR#RE12080003,
GFPR#RE13010012, GFPR#RE13020020)
2. Print data that contains many intricate curve lines might take a long time to print.
(GFPR#RE13030010)
3. A PCL XL error might occur when using the Citrix UPD to print.
1.04
Symptom corrected:
1. SC899 caused by the printing of specific kinds of TrueType fonts in PCL jobs.
(GFPR#RE11070014, GFPR#RC12050012, GFPR#RE12080003)
echnical
T
Troubleshooting
Mechanical
Paper path
Product Safety
M0525796G
M0525796F
M0525796E
M0525796D
M0525796C
M0525796B
M0525796A
Modified Points or Symptom Corrected
ulletin
B
Date:
Part information
Electrical
Transmit/receive
Other (Firmware)
Effective Date
July 2015 production
October 2014 production
December 2013 production
December 2012 production
July 2012 production
October 2011 production
1st Mass production
No
10-Aug-11
.: RM052007f
Prepared by:
T. Tachibana
Action required
Service manual revision
Retrofit information
Tier 2
Availability of RFU
Available
Available
Available
Available
Available
Available
Available
PAGE: 1/2