Open Loop Filter - Danfoss PVED-CLS User Manual

Controller for electrohydraulic steering
Hide thumbs Also See for PVED-CLS:
Table of Contents

Advertisement

ENGINEERING TOMORROW

11.3 OPEN LOOP FILTER

As a risk mitigation method, Danfoss wants to avoid unintended spool actuation, etc. when driving on bumpy-ground,
therefore an open loop joystick and open loop mini-steering wheel signal filter has been applied to the PVED-
steering wheel control algorithm.
Practically, if open loop mini-steering wheel has been selected as steering type, any mini-steering wheel signals, i.e.
where the steering angle velocity is below the value in P3649, will be disregarded.
Furthermore, if open loop joystick steering type has been selected, any joystick flow commands below the value in
P3648 will be disregarded.
Name
AUX Joystick no-
P3648
U8
activation threshold
AUX - Mini-steering no-
P3649
U8
activation threshold
Description of parameter
Min Flow command from AUX joystick below which the flow command
IR
of 0 is used by the AUX control algorithm
Min AUX steering angle velocity value below which the angle velocity of
dRpm
0 is used by the AUX control algorithm
Table 40
Range
OEM
0
100
OEM
0
100
5
5