ENGINEERING TOMORROW
Mapped cyl. str. vol.
(steering right) at 33%
P3823
U16
VB
Mapped cyl. str. vol.
(steering right) at 67%
P3825
U16
VB
Mapped cyl. str. vol.
(steering right) at 100%
P3827
U16
VB
Mapped VB for cyl. str.
P3829
U16
vol. (steering right)
The operator needs to map the sensor characteristics, according to Figure 16. The operator should map the cylinder
stroke volume @ 33% (P3823), 67% (P3825) and 100% (P3827) of the voltage base (P3829), where voltage base is:
The absolute voltage [mVolts] from the WAS, going from neutral to right most position, when maximum possible steer
angles can be achieved on the vehicle + some tolerance.
Automatic adjusted
cylinder stroke volume
(steering right)
P3827
P3825
P3823
Name
Mapped max. WA
P3831
U8
(steering left) at 33% VB
Mapped max. WA
P3832
U8
(steering left) at 67% VB
Mapped max. WA
(steering left) at 100%
P3833
U8
VB
Mapped VB for max.
P3834
U16
WA (steering left)
ccm
Mapped cylinder stroke volume (steering right) at 33% voltage base
ccm
Mapped cylinder stroke volume (steering right) at 67% voltage base
ccm
Mapped cylinder stroke volume (steering right) at 100% voltage base
mVolts
Mapped voltage base for cylinder stroke volume (steering right)
0.33
0.67
Description of parameter
deg
Mapped maximum wheel angle (steering left) at 33% voltage base
deg
Mapped maximum wheel angle (steering left) at 67% voltage base
deg
Mapped maximum wheel angle (steering left) at 100% voltage base
mVolts
Mapped voltage base for maximum wheel angle (steering left)
Table 24
|Captured right most position – Captured neutral position|
1.00
Figure 16
Table 25
OEM, Dealer
100
10000
OEM, Dealer
100
10000
OEM, Dealer
100
10000
OEM, Dealer
0
6000
P3829
Range
OEM, Dealer
0
89
OEM, Dealer
0
89
OEM, Dealer
0
89
OEM, Dealer
0
6000
333
667
1000
2000
30
60
89
2000
Need help?
Do you have a question about the PVED-CLS and is the answer not in the manual?