The range is from 100 to 1000 [IR] for P3708 (i.e. relative soft-stop flow limit).
The range is from 0 to 1000 [IR] for P3710 and P3712 (i.e. relative wheel angle).
The Danfoss recommended values are P3708 set to 200, and P3710 and P3712 set to 0.
Important
For wheel angles lower than the one specified at Point A, maximum flow is available.
Important
If soft-stops are not needed, the operator can eliminate those by setting P3708 to 1000.
Name
AUX Soft-stop max flow
P3708
U16
@ cylinder end-stop
AUX Soft-stop wheel
P3710
U16
angle region start
AUX - open loop soft-stop
200
300
400
500
Description of parameter
IR
Oil flow to deliver at the max possible wheel angle
Defines the wheel angle region start, from the max possible wheel angle
IR
towards 0, in which the soft stop has to be applied