Sehs Fda - Danfoss PVED-CLS User Manual

Controller for electrohydraulic steering
Hide thumbs Also See for PVED-CLS:
Table of Contents

Advertisement

ENGINEERING TOMORROW

16.3.2 SEHS FDA

Name
Fault Detection
Algorithm - Steering
P3122
U8
wheel activation
velocity threshold
Fault Detection
Algorithm min. wheel
P3123
U8
angle movement
threshold
Fault Detection
Algorithm wheel
P3124
U8
angle sensor delay
Fault Detection
Algorithm - Fault
P3125
U8
confidence counter
decrease rate
Fault Detection
Algorithm - Fault
P3126
U16
confidence counter
timeout
Fault Detection
Algorithm - Spool in left
P3128
S16
position range offset
Fault Detection
Algorithm - Spool in
P3130
S16
right position range
offset
Fault Detection
Algorithm Safe state
P3132
U8
upon a failure detection
Fault-Detection
Algorithm - Backlash
P3133
U8
region
Fault-Detection
Algorithm - Vehicle
P3134
U8
Speed Threshold
Description of parameter
Steering wheel angle velocity threshold used in the Fault Detection
dRpm
Algorithm to detect the steering wheel activation
Minimum wheel angle difference necessary to observe in order to make
the Fault Detection Algorithm assume that the wheels are moving. The
IR
difference is calculated between the current WA position and WA
number of loops back. Number is defined by P3124.
Number of loops between samples that are being compared against
x10mSec
P3123 for WA motion determination
Rate at which the Fault Detection Algorithm confidence counter value
x10mSec
decreases if an error is no longer observed
x10mSec
Time period for which error shall be observed by FDA to report failure
x10u Meter
Distance from closed loop dead-band to check if spool in left side
x10u Meter
Distance from closed loop dead-band to check if spool in right side
FDA safe state trigger Enable/Disable after failure detection.
Valid Values: 0 (DISABLE); 255 (ENABLE)
Warning
BOOL
DISABLE should only be used when diagnosis of the wheel angle
sensor and SASA failure modes are ensured by anther monitoring
function or when getting initial data for FDA tuning
Backlash limit to use in the backlash filter in the FDA control algorithm
dDeg
exclusively
Resolution: 1dDeg = 0.1Deg
Will disable the FDA and spool monitoring if speed of the vehicle goes
below this value. Should only be changed if EHPS/OSPE system is
Kmph
underpowered, hence the system does not have enough pressure to
move the wheels (normally when vehicle is not moving)
Table 58
Range
OEM
0
150
OEM
0
200
OEM
1
20
OEM
1
10
OEM
0
2000
OEM
-200
200
OEM
-200
200
OEM
0
255
OEM
0
200
OEM
0
10
5
S
50
S
1
S
1
S
50
S
0
S
0
S
0
S
5
S
0
S

Advertisement