16.2 FMI LIST

In PVED-CLS the standard FMI from J1939-73 Appendix A page 130 are used as much as possible. However, in some
PVED-CLS is found below:
Index
Failure mode
0
0 - Data valid, but above normal operational range - Most severe level
1
1 - Data valid, but below normal operational range - Most severe level
2
2 - Data erratic, intermittent or incorrect
3
3 - Voltage above normal or short-circuit to high source
4
4 - Voltage below normal or short-circuit to low source
5
5 - Current below normal or open circuit
6
6 - Current above normal or grounded circuit
7
7 - Mechanical system not responding or out of adjustment
8
8 - Abnormal frequency or pulse width or period
9
9 - Abnormal update rate
10
10 - Abnormal rate of change
11
11 - Unknown root-cause
12
12 - Bad intelligent device or component
13
13 - Out of calibration
14
14 - Special instructions
15
15 - Data valid, but above normal operating range - Least severe level
16
16 - Data valid, but above normal operating range - Moderately severe level
17
17 - Data valid, but below normal operating range - Least severe level
18
18 - Data valid, but below normal operating range - Moderately severe level
19
19 - Received network data in error
20
20 - Data drifted high
21
21 - Data drifted low
22
22 - Message missing
23
23 - Unintended Steering
24
24 – Reserved
25
25 - Signal crosscheck failed
26
26 - No steering
27
27 - Unable to return to neutral
28
28 - Not in neutral at Power-up
29
29 - Stuck Open
30
30 - Stuck Closed
31
31 - Condition exists
Table 56