Bosch Rexroth IndraMotion MTX 09VRS Manual page 204

Standart nc opeation
Table of Contents

Advertisement

192/233
Bosch Rexroth AG | Electric Drives
Extended Functionality
Quadrant Error Clearance Dialog
Rexroth IndraMotion MTX 09VRS | Application Description
and Controls
saves a completed measurement with all settings related to
axis selection, feed and radius.
<F5>
"Add measurement"
loads a measurement to the current measurement to compare
them with each other. The scaling of the measurement added
is adopted to the current measurement.
<F6>
"Print result"
Retrieving the print preview The document can be printed from
here. The configuration data are also printed.
<F7>
"Zoom"
changes into another level of F-keys "Zoom"
<F8>
"Back to configuration"
Changes back to the configuration screen.
<F9>
"Quadrant - error clearance"
Opens the Quadrant error clearance dialog
There are the following possibilities in the zoom area:
<F3>
"Select graph"
switches between the two loaded curves.
<F4>
"Cursor backwards"
can move the cursor backward in the zoomed curve with regard
to time.
<F5>
"Cursor forwards"
can move the cursor forwards in the zoomed curve with regard
to time.
<F7>
"Zoom level back"
shows the zoom area selected before.
<F8>
"Zoom 1:1"
Zoom 1:1 shows the whole measurement on the screen.
<F9>
Back to the default F-keys.
This dialog is used to enter the drive parameters P435 - P439 for error clearance
at the quadrant intersections of the circle. To be able to change the parameters,
the drive needs to be in "Closed Loop" and the optional servo package needs
to be switched on. The following quadrant error clearance dialog opens:

Advertisement

Table of Contents
loading

Table of Contents