Application Description | Rexroth IndraMotion MTX 09VRS
The number of error message and mes‐
sage text
(#88) It is not possible to set one or more
breakpoints after loading a configuration
file. The breakpoints will be deleted from
the list of breakpoints.
(#90) When a configuration file has been
loaded, it is not possible to set active
breakpoints because the test mode is not
set.
(#20) The number of variables cannot be de‐
termined. (IVariable::GetNumberOfVaria‐
ble)
(#22) The current variable value cannot be
determined. (IVariable::GetVarValue)
(#28) The current NC status cannot be de‐
termined. (INcsChannel::GetNcState)
(#32) The current NC mode cannot be de‐
termined. (INcsChannel::GetNcMode)
(#50) The depth of the call stack cannot be
determined. (IProgChain::GetProgChain‐
Deep)
(#51) The parameters of a subroutine cannot
be determined. (IProgChain::GetSubPro‐
gLevel)
(#80) The connection to the NC was inter‐
rupted.
The probable reason
Active flow program was absent at
the moment of loading information
from the configuration file.
The regime NC-Analyzer Mode
was not set.
The configuration file was written
during the work with another flow
program.
The flow program was edited after
its data were saved in the configu‐
ration file.
The regime DryRunMode was not
set.
Messages about problems of connection with NC
Timeout is too small.
Timeout is too small.
Timeout is too small.
Timeout is too small.
Timeout is too small.
Timeout is too small.
The break of connection with NC. Close the application and restart it, restoring
Electric Drives
| Bosch Rexroth AG
and Controls
Extended Functionality
Recommendations to a user
Load information from the configuration file
only after selecting active flow program.
Set NC-Analyzer Mode.Then (DryRunMode
also should be set) load information from the
configuration file.
Continue the work (information about break‐
points from this configuration file will be lost).
If it is necessary to save information about
breakpoints, written just in the configuration
file, with which the application was started,
then, save the configuration file with another
name for further usage, without closing the
application.
It is recommended to juxtapose configuration
files to concrete flow programs, and to start
flow programs only with their own configura‐
tion files. (For instance, it is possible to use
the name of the flow program for the name of
the configuration file: TEST.CPL
This message will not appear if this recom‐
mendation is taken into consideration.
Continue the work (information about break‐
points from this configuration file will be lost).
Set DryRunMode, clicking the button General
Inhibit OFF.Then (NC-Analyzer Mode also
should be set) load information from the con‐
figuration file.
Close the application, restart the application.
Close the application, restart the application.
Close the application, restart the application.
Close the application, restart the application.
Close the application, restart the application.
Close the application, restart the application.