Application Description | Rexroth IndraMotion MTX 09VRS
No.
Window in the
NC analyzer
1
Variables
2
Watch
3
Watch values
4
Program
5
Quick Watch
6
Quick Watch values
7
Stack
8
Output
9
File
F-Key Bars
Function
Displays of all CPL variables used in the pro‐
gram in tree form, structured according to the
following groups:
Permanent
Defined permanent
Global
Local
Watch variables asynchronously:List of selec‐
ted variables. The current values are displayed
in the "WATCH VALUES" window.
Show values:Display of the variable values
from the "WATCH" window during the runtime
of the program.
Program window:Showing
The operating mode as icon, the channel
( $x) as well as the program name includ‐
ing path
Program code
The block processed at runtime
Breakpoints
Read-protected programs are not shown.
Watch variables synchronously:List of selected
variables. The current values are displayed in
the "QUICK WATCH VALUES" window.
Show values synchronously:Display of the var‐
iable values from the "QUICK WATCH" window
during the runtime of the program.
Select subroutine:Displays the subroutine
stacking of the selected NC program
Status display:Display of messages (MSG,
GMSG, etc.) and errors concerning the NC pro‐
gram and the NC analyzer.
File system: Display of the file system of the
control.
Below the work section there are 8 F-keys, which can be operated by mouse
or via the function keys F2...F9:
Active keys are shown with white writing
Keys that are inactive, e.g. because of a configured option, are shown in
grey.
The functions of the F-keys change depending on the active window in the work
section (see the following figure).
Select a window by:
Electric Drives
| Bosch Rexroth AG
and Controls
Extended Functionality
Possible entries
Select variables to be watched. They are
displayed in the "WATCH" window.
Delete the variables that are not be watch‐
ed any longer.
Editing the values of variables (with the
exception of simple string variables) dur‐
ing the runtime of the program.
Find text
Set, delete, activate, deactivate
breakpoints
Delete the variables that are not be watch‐
ed any longer.
Editing the values of variables (with the
exception of simple string variables) dur‐
ing the runtime of the program.
Selection of a subroutine from the sub‐
routine structure that is currently active.
Deleting the displays.
Selection of a program to be shown in the
"Program" window (this is not program se‐
lection in the control).
175/233