Leds On The Tm54F Terminal Module - Siemens SINAMICS S120 Device Manual

Cabinet modules nema
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Diagnostics

7.14 LEDs on the TM54F Terminal Module

7.14
LEDs on the TM54F Terminal Module
Table 7- 23
Meaning of the LEDs on the TM54F Terminal Module
LED
Color
READY
-
Green
Orange
Red
Green/Red
Green/Orange
or
Red/Orange
L1+, L2+,
Red
L3+
Red
Fail-safe inputs / double inputs
F_DI z
LED
LED
(input x,
x
x+1
(x+1)+,
Red
(x+1)-)
Red
LED
LED
x
x+1
Green
Green
Green
Green
Single digital inputs, not fail-safe
DI x
Green
346
Status
Off
The electronics power supply is missing or outside the permissible
tolerance range.
Continuous light The component is ready for operation, cyclic DRIVE-CLiQ communi-
cation is taking place.
Continuous light DRIVE-CLiQ communication is being established.
Continuous light At least one fault is pending on this component.
Note:
LED is activated irrespective of any reconfiguring of the corresponding
messages.
Flashing 0.5 Hz
Firmware is being downloaded.
Flashing 2 Hz
Firmware download has been completed. Waiting for POWER ON.
Flashing
Detection of the components via LED is activated (p0154).
Note:
The two options depend on the LED status when component detection
is activated via p0154 = 1.
On
The controllable sensor power supply is functioning fault-free.
Continuous light There is a fault in the controllable sensor power supply.
On
The sensor power supply is operating fault-free.
Continuous light The sensor power supply has a fault.
NC contact / NC contact
Continuous light Different signal states at input x and x+1
No signal at input x and no signal at input x+1
NC contact / NO contact
Continuous light Same signal states at input x and x+1
No signal at input x and one signal at input x+1
NC contact / NC contact
Continuous light One signal at input x and one signal at input x+1
NC contact / NO contact
Continuous light One signal at input x and no signal at input x+1
Off
No signal at digital input x (x = 20 to 23)
Continuous light Signal at digital input x
Description, cause
: (z = 0 to 9, x = 0, 2, to 18)
1)
: (z = 0 to 9, x = 0, 2, to 18)
1)
: (z = 0 to 9, x = 0, 2, to 18)
1)
: (z = 0 to 9, x = 0, 2, to 18)
1)
Cabinet Modules NEMA