Note
The temperature sensor connection can be used for motors that are equipped with a KTY84-
1C130 or PTC probe in the stator windings.
Note
EP terminals only for Safety Integrated Basic Functions
The function of the EP terminals is only available when Safety Integrated Basic Functions
are enabled.
Note
Safety Integrated Function Manual
Detailed and comprehensive instructions and information for the Safety Integrated functions
can be found in the associated Function Manual. This manual is available as additional
documentation on the customer DVD supplied with the device.
8.22.4.3
X46 Brake control and monitoring
Table 8- 30
Max. connectable cross-section: #14 AWG (2.5 mm
Fire hazard due to overheating when permissible connection cable lengths are exceeded
Excessively long connection cables connected to terminal strip X46 can cause components
to overheat with the associated risk of fire and smoke.
• Limit the connected cable lengths to a maximum of 35 ft (10 m).
• Do not route the connection cable outside the control cabinet or control cabinet group.
Cabinet Modules NEMA
Manual, 04/2014, A5E03586450A
Terminal block X46 on the customer terminal block X55
Terminal
Function
1
BR output +
2
BR output -
3
FB input +
4
FB input -
WARNING
8.22 K95, CU320-2 PN Control Unit
Technical specifications
This interface is intended for the connection of the
Safe Brake Adapter.
)