Siemens SINAMICS S120 Device Manual page 180

Cabinet modules nema
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Cabinet Modules
5.3 Smart Line Modules
Order no.
Weight (standard model)
Frame size
SCCR (short circuit current rating)
Minimum short-circuit current
The base load current I
1)
300 s.
The current demand for the 500/690 V AC auxiliary supply is provided by the supply input voltage.
2)
The specified power loss represents the maximum value at 100 % capacity utilization. The value in normal operation is
3)
lower.
Total of all motor cables and DC link. Longer cable lengths for specific configurations are available on request, see
4)
SINAMICS - Low Voltage Configuration Manual on the customer DVD supplied with the device.
The cabinet height increases by 10" (250 mm) with degree of protection IP21, and by 16" (400 mm) with degrees of
5)
protection IP23 (NEMA1 filtered), IP43, and IP54 (NEMA12 ventilated).
Minimum current required for reliable tripping of the contained protective devices.
6)
180
6SL3730-
lb
kg
kA IC
A
6)
is based on a duty cycle of 150 % for 60 s or I
H DC
6TG35-
6TG38-
5AU3
8AU3
750
1213
340
550
GX
HX
65
100
6200
10500
for 5 s with a duty cycle duration of
max DC
6TG41-
6TG41-
2AU3
7AU3
1753
1753
795
795
JX
JX
100
100
2500
3200