Options
8.24 L10, dv/dt filter plus Voltage Peak Limiter
Restrictions
The following restrictions must be taken into account when a dV/dt filter is used:
● The output frequency is limited to no more than 150 Hz.
● Maximum permissible motor cable lengths:
– Shielded cable: Max. 980 ft (300 m) (frame sizes FX, GX, HX) / 490 ft (150 m) (frame
– Unshielded cable: Max. 1,480 ft (450 m) (frame sizes FX, GX, HX) / 738 ft (225 m)
Table 8- 42
Table 8- 43
442
size JX)
(frame size JX)
Maximum permissible motor cable lengths for the DC link voltage 510 - 720 V DC
Frame sizes FX, GX, HX
Shielded cable max. 980 ft (300 m) or
unshielded cable max. 1480 ft (450 m)
6SL3720-1TE32-1AU3
6SL3720-1TE32-6AU3
6SL3720-1TE33-1AU3
6SL3720-1TE33-8AU3
6SL3720-1TE35-0AU3
6SL3720-1TE36-1AU3
6SL3720-1TE37-5AU3
6SL3720-1TE38-4AU3
Maximum permissible motor cable lengths for the DC link voltage 675 - 1035 V DC
Frame sizes FX, GX, HX
Shielded cable max. 980 ft (300 m) or
unshielded cable max. 1480 ft (450 m)
6SL3720-1TG28-5AU3
6SL3720-1TG31-0AU3
6SL3720-1TG31-2AU3
6SL3720-1TG31-5AU3
6SL3720-1TG31-8AU3
6SL3720-1TG32-2AU3
6SL3720-1TG32-6AU3
6SL3720-1TG33-3AU3
6SL3720-1TG34-1AU3
6SL3720-1TG34-7AU3
6SL3720-1TG35-8AU3
Frame size JX
Shielded cable max. 490 ft (150 m) or
unshielded cable max. 738 ft (225 m)
6SL3720-1TE41-0AU3
6SL3720-1TE41-2AU3
6SL3720-1TE41-4AU3
-
-
-
-
-
Frame size JX
Shielded cable max. 490 ft (150 m) or
unshielded cable max. 738 ft (225 m)
6SL3720-1TG37-4AU3
6SL3720-1TG38-1AU3
6SL3720-1TG38-8AU3
6SL3720-1TG41-0AU3
6SL3720-1TG41-3AU3
-
-
-
-
-
-