7.13

LEDs on the SMC30 Sensor Module

Table 7- 22
Meaning of the LEDs on the SMC30 Sensor Module
LED
Color
---
Green
Orange
Red
RDY
(READY)
Green/
Red
Green/
Orange
or
Red/
Orange
-
OUT > 5
Orange
V
Cabinet Modules NEMA
Manual, 04/2014, A5E03586450A
Status
Description
Off
The electronics power supply is missing or lies outside the permissible tolerance
range.
Continu-
The component is ready for operation and cyclic DRIVE-CLiQ communication is
ous light
taking place.
Continu-
DRIVE-CLiQ communication is being established.
ous light
Continu-
At least one fault is present in this component.
ous light
Note:
LED is activated irrespective of any reconfiguring of the corresponding messages.
Flashing
Firmware is being downloaded.
0.5 Hz
Flashing
Firmware download is being completed.
2 Hz
Waiting for POWER ON.
Flashing
Detection of the component via LED is activated (p0144).
Note:
The two options depend on the LED status when component detection is activated
via p0144 = 1.
Off
The electronics power supply is missing or lies outside the permissible tolerance
range.
Power supply ≤ 5 V.
Continu-
The electronics power supply for the measuring system is available.
ous light
Measuring system supply > 5 V
Notice:
You must ensure that the connected encoder can be operated with a 24 V power
supply.
If an encoder that is designed for a 5 V supply is operated with a 24 V supply, this
can destroy the encoder electronics.
7.13 LEDs on the SMC30 Sensor Module