Diagnostics
7.2 LEDs on the CU320-2 DP Control Unit
LED
Color
OPT
(OPTION)
Green
Red
RDY and
Red
COM
RDY and
Orange
OPT
332
Status
Off
Electronics power supply is missing or outside
the permissible tolerance range.
Component is not ready.
Option board not installed or no associated drive
object has been created.
Continuous
Option board is ready.
light
Flashing
Depends on the option board used.
0.5 Hz
Flashing
At least one fault is pending on this component.
2 Hz
Option board not ready (e.g., after switching on).
Flashing
Bus fault – communication has been interrupted
2 Hz
Flashing
Firmware update in progress for connected Op-
0.5 Hz
tion Board CBE20.
Description, cause
Remedy
Check power supply and/or
component
Remedy and acknowledge
fault
Eliminate the fault
-