5.5.2.2

Customer terminal block X55.1

Description
The customer terminal block (-X55.1) is mounted as standard in the cabinet for each
Booksize Cabinet Kit. It provides the function-related inputs/outputs for temperature
monitoring and for the "Safe Torque Off" and "Safe Stop 1" functions.
Note
Additional information
All other cabinet interfaces and connections are explained in the circuit and terminal
diagrams on the customer DVD supplied.
X55.1 customer terminal block
Table 5- 27
Customer terminal block -X55.1
Terminal
Designation
1
+ Temp
2
- Temp
3
EP +24 V
enable pulses
4
EP M1
enable pulses
Max. connectable cross-section: #14 AWG (2.5 mm
Risk of death from electric shock in the event of voltage flashovers at the temperature
sensor
Voltage flashovers in the signal electronics can occur in motors without safe electrical
separation of the temperature sensors.
• Only use temperature sensors that fully comply with the specifications of the electrical
• If safe electrical separation cannot be guaranteed (for linear motors or third-party
Cabinet Modules NEMA
Manual, 04/2014, A5E03586450A
Technical specifications
Temperature sensor connection KTY84-1C130 / PTC / bimetallic switch with
NC contact
Supply voltage: 24 V DC (20.4 to 28.8 V)
Power consumption: 10 mA
Isolated input
Signal propagation times:
L → H: 100 µs
H → L: 1000 µs
The pulse inhibit function is only available when Safety Integrated Basic Func-
tions are enabled.
WARNING
separation.
motors, for example), use a Sensor Module External (SME120 or SME125) or the
Terminal Module TM120.
)