Cabinet Modules
5.5 Booksize format Motor Modules
Mounting grid arrangement in the cabinet
The area for connecting the Motor Modules in the cabinet is divided into three grid widths:
● 4" (100 mm)
● 8" (200 mm)
● 12" (300 mm)
The table below shows the grid width assigned to the various Motor Modules.
Table 5- 26
Grid width
4" (100 mm)
8" (200 mm)
12" (300 mm)
Note
Available space in the Booksize base cabinets
The space available for the Motor Modules in the Booksize base cabinets is determined by
taking the actual space and subtracting a clearance of 8" (200 mm).
5.5.2

Interface description

5.5.2.1

General information

This section describes only those interfaces in the cabinet unit that require additional
connection work by the customer. All other interfaces are pre-wired at the factory and are not
designed for customer connections.
Note
Additional information
All connections to be established on the plant side as well as the interfaces for integration
into the plant control system are described in the circuit diagrams and terminal diagrams on
the customer DVD supplied with the device.
204
The assignment of the Motor Modules according to grid width
Assignment of Motor Modules (see the section "Technical specifications")
9 ... 30 A Motor Modules
45 to 85 A Motor Modules
132 A Motor Module
Cabinet Modules NEMA