Table A-2 Upgrade Options - Cisco BPX-BXM-155-8DX Installation And Configuration Manual

Cisco bpx-bxm-155-8dx: user guide
Table of Contents

Advertisement

Appendix A
Upgrade Information
Table A-2
Upgrade Options
Option
Used when...
Yred BXMs,
Legacy BXMs are yred
manual
and the "auto BXM
upgrade parameter" is
set to "N" for the
cnfnodeparm
command.
Yred BXMs,
Legacy BXMs are yred
automatic
and the "auto BXM
upgrade" parameter is
set to Y for the
cnfnodeparm
command.
Release 9.3.0, Part Number 78-10674-01 Rev. D0, July 2001
Steps
1.
Remove the standby BXM card and replace it with the BXM-E card.
2.
BXM-E card can be flagged as 'Mismatch' if the configured channel
statistics level or number of connections is smaller than those configured on
the active BXM card. Use the command cnfcdparm <BXM-E slot_num> to
configure the desired level of channel statistics and number of connections,
if not already configured. The BXM-E card is reset after the cnfcdparm
command is executed. After the BXM-E card boots, there should be no
mismatch.
Yred the switch so that the standby BXM-E becomes active.
3.
Repeat steps 1-2 for the other slot. User still can fall back to the legacy
4.
card up to this point.
Upgrade the logical card using the command upgdlogcd <log_card_num>.
5.
Switch software upgrades the logical database from the number of
connections configured on the legacy BXM card to the number of
connections configured in step 2 and 4. From this point on, mismatch is
declared if the legacy card is reinserted.
During upgrading yred BXM cards to BXM-E cards, the
Note
level of service disruption is expected to be the same as the
one experienced when switchyred is executed for yred
legacy BXMs.
Remove the standby BXM card and replace it with the BXM-E card.
1.
BXM-E card can be flagged as 'Mismatch' if the configured channel
2.
statistics level or number of connections is smaller than those configured on
the active BXM card. Use the command cnfcdparm <BXM-E slot_num> to
configure the desired level of channel statistics and number of connections,
if not already configured. The BXM-E card is reset after the cnfcdparm
command is executed. After the BXM-E card boots, there should be no
mismatch.
3.
Yred switch so that the standby BXM-E becomes active.
4.
Repeat steps 1-2 for the other slot.
5.
Switch software automatically upgrades the logical database when step 4 is
done.
During upgrading yred BXM cards to BXM-E cards, the
Note
level of service disruption is expected to be the same as the
one experienced when switchyred is executed for yred
legacy BXMs.
Cisco BPX 8600 Series Installation and Configuration
Upgrade Options
A-3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents