Event Logging; Error Messages; Table 28-6 Igx Log Messaging For Activating And Adding Vt; Table 28-7 Bpx Log Messaging For Activating And Adding Vt - Cisco BPX-BXM-155-8DX Installation And Configuration Manual

Cisco bpx-bxm-155-8dx: user guide
Table of Contents

Advertisement

Chapter 28
Alarms and Statistics

Event Logging

All trunk log events are modified to display the virtual trunk number. The examples in Table 28-6 and
Table 28-6 and Table 28-7 show the log messaging for activating and adding a virtual trunk 1.2.1.

Table 28-6 IGX Log Messaging for Activating and Adding VT

Class
Info
Clear
Major
Clear

Table 28-7 BPX Log Messaging for Activating and Adding VT

Class
Info
Clear
Major
Clear

Error messages

Added error messages for virtual trunks are listed here:
Message
"Port does not support virtual trunking"
"Port configured for virtual trunking"
"Invalid virtual trunk number"
"Maximum trunks per node has been
reached"
"Invalid virtual trunk VPI"
"Invalid virtual trunk traffic class"
"Invalid virtual trunk VPC type"
"Invalid virtual trunk conid capacity"
"Mismatched virtual trunk configuration"
"Maximum trunks for card has been
reached"
Release 9.3.0, Part Number 78-10674-01 Rev. D0, July 2001
Description
NodeB at other end of TRK 1.2.1
TRK 1.2 OK
TRK 1.2 Loss of Sig (RED)
TRK 1.2.1 Activated
Description
NodeB at other end of TRK 1.2.1
TRK 1.2.1 OK
TRK 1.2.1 Loss of Sig (RED)
TRK 1.2.1 Activated
Description
Port is not configured for virtual
trunks
Port is not configured for a physical
trunk
Virtual trunk number is invalid
Trunk limit per node has been reached
Virtual trunk VPI is invalid
Virtual trunk traffic class is invalid
Virtual trunk VPC type is invalid
Virtual trunk conid capacity is invalid
Ends of virtual trunk have different
configuration
The trunk card is out of VIs
Cisco BPX 8600 Series Installation and Configuration
Event Logging
28-13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents