During the process of acceleration, if the running frequency is
smaller than the value of PB.25, acceleration time 2 is selected. If
the running frequency is larger than the value of PB.25, acceleration
time 1 is selected.
During the process of deceleration, if the running frequency is
larger than the value of PS.26, deceleration time 1 is selected. II the
running frequency is smaller than the value of P8.26, deceleration
time 2 is selected.
Terminal
PB.27
S tti
ng
6
It is used to set whether terminal JOG is the highest priority.
If terminal JOG is preferred, the AC drive switches to terminal JOG
running state when there is a terminal JOG command during the
running process of the AC drive.
Frequency detection value
(FDT2)
PB.28
Setting Range !O.OOHz-maximum frequency
Frequency detection
hysteresis (FDT2)
PB.29
Setting Range !0.0%-100.0% (FDT2 level)
The frequency detection function is the same as FDT1 function. For
derails, refer to tho descriptions of PS. 19 and P8.20.
Any frequency reaching
PB.30 detection value
Setting Range I0.00 Hz- maximum frequency
Any frequency reaching
PB.31 detection amolitude
Setting Range 10.0%-100.0% (maximum frequency)
Any frequency reaching
PB.32 detection value 2
Setting Range IO.OOHz-maximum frequency
Any frequency reaching
PB.33 detection amolitude 2
Setting Range 10.0%-100.0% (maximum frequency)
If the output frequency of the AC drive is w ithin t he p ositive and
negative amplitudes of the any frequency reaching d etection value,
tho corresponding M01 outputs ON(P6.01�26127).
MT-
The
2000 provides two groups of any frequency reaching
detection parameters, including frequency detection value and
prafarmd
JOG
Dl&abled
Ra
nge
1: Enabled
1
1
Detailed Function
Def It
au
Default
Default