abc 2000 Series User Manual page 73

Table of Contents

Advertisement

M01 output delay tima
P6.17
Setting Range
M RB�RC output delay
1me
P6.18
Setting Range
These parameters are used to set the delay time of output terminals
M01, relay
trom sta1us change to actual output.
1
Output terminal valid mode Default
selection
P6.22
Setting Range 1
It is used to definite !he logic of output terminals M01,RA,RB,RC.
0: Positive logic
The output terminal is valid when it is connected with GND, and
invalid when it is disconnected from GND.
1: Negative logic
The output terminal is invalid when it is connected with GND, and
valid when it is disconnected from GND.
Group Pl': Operation Panel and Display
Output power
P7.00 correction factor
Setting Range I 0
Can correct output power by modifying para.meter P7 .00, (output
power can be viewed through 1he parameter D0.05)
P7 .01 Reserved
STOP/RESET key
function
P7.02
Setting Range
Default
Unit's digit M01 valid model
Positive logic
0
RA.mRBmRC valid mode {0-1, the same
Ten's
digit
as M01)
Default
0.0-200.0
Default
STOP/RESET key enabled only
0
operation panel control
STOP/RESET key enabled in any
1
operation mode
in