abc 2000 Series User Manual page 157

Table of Contents

Advertisement

Function
Parameter
Name
Code
P9.14
1st fault
P9.15
2nd fault type
3rd (latest) fault 17: Contactor fault
P9.16
type
Frequency upon
P9.17
3rd fault
Setting Range
0: No fault
1 : Inverter unit protection
2: Overcurrenl during
acceleration
3: Overcurrant during
deceleration
4: Overcurrent at constant
speed
5: Overvoltage during
acceleration
6: Overvoltage during
deceleration
7: Ovarvoltage al constant
speed
8: Buffer resistance ovar1oad
9: Undervoltage
10: AC drive over1oad
11: Motor over1oad
12:Reserved
13: Power output phase loss
14: Module overheat
15: External equipment fault
16: Communication fault
18: Current detection fault
19: Motor auto-tuning fault
20: Reserved
21: EEPROM read-write fault
22: AC drive hardware fault
23: Short circuit lo ground
24: Reserved
25: Reserved
26:Accu m ulative running lime
reached
27: Reserved
28: Reserved
29: Accumulative power-<:1n
time reached
30: Load becoming 0
31: PIO feedback lost during
running
40: With-wave current limit
fault
41-43: Reserved
51: Reserved
-
152
·
·