FOV measured voltage
CC.13
Setting Range I0.500V-4.000V
FOV taraet volta a e
CC.14
Setting Range IB.OOOV-9.999V
FOV measured voltage
CC.15
CC.16
Reserved
CC.17
Reserved
CC.18
Reserved
CC.19
Reserved
These parameters are used to correct the FOV.
They have been corrected upon delivery. When you resume
the factory values, these parameters will be restored to the
factory-corrected values. You need not perform correction in the
applications.
Target voltage indicates the theoretical output voltage of the AC
drive. Measured voltage indicates the actual output voltage value
measured by instruments such as the multimeter.
Group
DO: Monitoring Par ameters
Group DO is used to monitor the AC drive's running state. You can
view the parameter values by using operation panel, convenient
for on-site commissioning, or from the host computer by means of
communication .
D0.00 to D0.31 are the monitoring parameters in the running and
stopping state defined by P7.03 and P7.04.
For more details, see Table
Parameters of Group DO:
Function
Code
DO.DO
D0.01
D0.02
D0.03
D0.04
D0.05
DO.OB
D0.07
D0.08
D0.09
1
2
2
Parameter Name
Running frequency
(V)
Bus voltage
(V)
Output voltage
Output current (A)
Output torque (%)
S input state
M01 outcut state
Reserved
116
·
Factory-corrected
Factory-corrected
(Hz)
·
Unit
0.01Hz
0.01Hz
0.1V
1V
0.01A
0.
kW
1
0.
%
1
1
1