set this parameter to a proper value in actual applications.
Set the over-excitation gain to O in applications of small inertia (the
bus voltage will not rise during deceleration) or where there is a
braking resistor.
T orque upper limit source in
speed control mode
P3.09
Setting Range
digital
limit in speed control mode
P3.10
Setting Range
In the speed control mode, the maximum output torque of the AC
drive is restricted by P3.09. If the torque upper limit is analog, pulse
or communication setting, 100% of the setting corresponds to the
value of P3.10, and 100% of the value of P3.10 oorresponds
AC drive rated torque.
Excitation adjustment
proportlonal
P3.13
Setting Range
Excitation adjustment
P3.14
Setting Range
T orque adjustment
proportional aain
P3.15
Setting Range
T orque adjustment
integral gain
P3.16
Setting Range
Speed loop integral
property lype
P3.17
Setting Range
These are current loop Pl parameters for vector control. These
parameters are automatically obtained through "Asynchronous
motor complete auto-tuning", and commonly need not be modified.
The dimension of the current loop integral regulator is integral gain
rather than integral time.
n
setti
g
torque upper
of
Default
Default
Default
Default
Default
Detailed Function
Default 0
0
P3.10
FIV
2
FIC
3
Reserved
4
Pulse setting
5
Communication setting
Default
0-20000
0-20000
0-20000
0-20000
o
1 Valid
150.0%
0.0%-200.0%
Invalid
ro