Pb.04 specifies the time percentage of triangular wave rising time to
Pb.03 (Swing frequency cycle).
Triangular wave rising time = Pb.03 (Swing frequency cycle) x Pb.04
(Triangular wave rising time coefficient, unit: s)
Triangular wave falling time = Pb.03 (Swing frequency cycle} x
Pb.04 Triangular wave rising time coefficient ,unit: s)
Set length
Pb. 0 5
Setting Range
Actual length
Pb. O S
Number
Pb. 0 7
meter
The preceding parameters are used for fixed length control.
The length information is collected by multifunction digital terminals.
Pb.06 (Actual length) is calculated by dividing the numbers of
pulses collected by the S terminal by Pb.07 (Number of pulses each
meter}.
When the actual length Pb.06 exceeds the set length in Pb.05, lhe
M01 terminal allocated with function 1 0 (Length reached) becomes
ON.
During the fixed length control, the length reset operation can be
performed via the S terminal allocated with function 28. For details,
see the descriptions of P5.00 to P5.09.
Allocate corresponding S terminal with function 27 (Length count
input} in applications. If the pulse frequency is high,83 must be
used.
Set count value
Pb. O B
Pb.09
Setting Range
The count value needs to be collected by multi-function input
terminals. Allocate the corresponding input terminals with function
25 (Counter input) in applications. If the pulse frequency is high, S3
must be used.
When the count value reaches the set count value (Pb.08), the
M01 terminal allocated with function 8 {Set count value reached)
becomes ON. Then the counter stops counting.
When the counting value reaches the designated counting value
of
pulses per
1-65535