This parameter is used to select the base value of the swing
amplitude.
O: Relative to the central frequency (P0.03 frequency source
selection}
It is variable swing amplitude system. The swing amplitude varies
with the central frequency (set frequency).
1 : Relative to the maximum frequency (P0.12 maximum output
frequency)
It is fixed swing amplitude system. The swing amplitude is fixed.
Pb.01
Seiling Range
Jump frequency amplitude
Pb.02
This parameter is used to determine the swing amplitude and jump
frequency amplitude.
The swing frequency is limited by the frequency upper limit and
frequency lower limit.
If relative to tho central frequency (Pb.00 " 0), tho actual swing
amplitude AW is the calculation result of P0.03 (Frequency source
selection} multiplied by Pb.01.lf relative to the maximum frequency
(Pb.00 = 1 )
the actual swing amplitude AW is the calculation result
,
of P0.12 (Maximum frequency) multiplied by Pb.01.Jump frequency
= Swing amplitude AW • Pb.02 (Jump frequency amplitude). If
relative to the can1ral frequency (Pb.00
variable value. If relative to the maximum frequency (Pb.00
jump frequency is a fixed value.
The swing frequency is limited by the frequency upper limit and
frequency lower limit.
Svving frequency cycle
Pb.03
Setting Range
Triang � larwave rising time
Pb.04
coefficient
Setting Range
Swing frequency cycle: the time of a complete swing frequency
cycle.
Default
Default
=
0), 1ha jump frequency is a
Default
Default
00
1
·
·
1), 1he
=