Operating the Processor at 50-Hz
The processor is shipped for 60 Hz
operation. If you plan to operate the
processor at 60 Hz, proceed to the
next section entitled ''Installing
Language Chips'' on page ??. If you
plan to operate the processor at 50 Hz,
read the section that follows.
[1]
Deenergize the processor by moving the
MAIN CIRCUIT BREAKER, CB1, and
AUXILIARY CIRCUIT BREAKERS CB2, CB3,
and CB4 to the ''O'' position.
[2]
Remove the FEED-END, MIDDLE ACCESS
PANEL from the processor.
[3]
Remove the BLOWER MOTOR COVER.
[4]
Move the BLOWER MOTOR to the inner set
of mounting holes, located on the frame of the
processor.
[5]
Remove the BLOWER MOTOR PULLEY.
[6]
Turn the BLOWER MOTOR PULLEY around
and install the PULLEY making sure that the
larger diameter end of the PULLEY is
mounted against the BLOWER MOTOR
MOUNTING FRAME. See Figure ??
[7]
Move the DRIVE BELT to the larger diameter
part of the BLOWER MOTOR PULLEY.
[8]
Adjust the position of the BLOWER MOTOR
to obtain the correct tension of the BLOWER
DRIVE BELT.
Correct belt tension is achieved when
the BLOWER DRIVE BELT does not
make loud noises when you energize
the processor.
[9]
Energize the processor by moving the MAIN
CIRCUIT BREAKER, CB1, to the ''I'' position
to check for correct tension of the BLOWER
DRIVE BELT.
[10]
Deenergize the processor by moving the
MAIN CIRCUIT BREAKER, CB1, to the ''O''
position.
636738
NOTE
NOTE
MAIN
CIRCUIT BREAKER
(CB1)
AUXILIARY CIRCUIT BREAKERS
CB2, CB3, and CB4
Figure 32 Deenergizing the Processor
MIDDLE
ACCESS
PANEL
H108_0002CCD
H108_0002CA
27