The following procedure must be performed by a qualified service person after the processor
installation is complete.
For this procedure all ACCESS PANELS including the TOP COVER must be removed from the
processor. See Figures ?? through ?? on page ?? for ACCESS PANEL locations.
Blower Motor Check
[1]
Remove the BLOWER MOTOR COVER. Check that the BLOWER MOTOR PULLEY is in the correct
position for your operating conditions (50 Hz operation or 60 Hz operation).
[2]
Check that the BLOWER DRIVE BELT is straight.
[3]
Install the BLOWER MOTOR COVER.
636738
System Check-Out
IMPORTANT
SMALL
DIAMETER
Figure 45
50 and 60 Hertz Blower Motor Operation
LARGE
DIAMETER
DRIVE
BELT
BLOWER
MOTOR
H108_0015BCA
H108_0015BA