Figure 85. TDSC Repair Kit with connection completed
For larger breaks and cuts than can be joined together via a single repair kit's terminal
block board, use both provided repair assemblies in the kit with a length of cable between
two good sections of cable. Follow the above process for both ends of the newly inserted
cable length.
Password Reset:
If a TCP/IP connection with the unit is possible, but the set username and passwords are
not granting access, a password reset may be necessary. To reset the passwords, first
remove the cover of the TD100 processor. Once removed, identify and hold down the test
button for 7 seconds.
Figure 86. Test button on TD100 PCB
Access is time-limited to 10 minutes after the reset. The reset sets the passwords back to
the factory defaults; see
TD100 Default Password
Table.
Confidential – Limited Distribution
Page 77