Step 13; Step 14 - Optex Fiber SenSys Terrain Defender TD 100 Installation Manual

Table of Contents

Advertisement

Step 13

Remove the lid from the Start-Up Module (SUM) by removing the screws on the two-hole
sensor clamp. Set it aside, being careful not to lose the screws.

Step 14

Flip-up the large orange lever of the center conductor terminal block and the two smaller
levers on each side of the large center block. Arrange the drain wire, so it is located on the
top of the cable. Place the cable shield onto the bottom portion of the SUM clamp while
inserting the center conductor into the large block. Once the center conductor is fully
inserted, close the lever on the large orange terminal block, as seen in Figure 51.
Insert the separated drain wire into the left and right terminal blocks,
two smaller levers. With all three blocks snapped into place, now moderately pull on both
braided wires and the center conductor to ensure a solid connection at each.
Figure 51. Center Conductor inserted
CAUTION: The cable shield and drain wire must not contact the center conductor, which
will cause a short on the system. Be sure after inserting the drain wire there are no loose
strands. Any loose strands should be trimmed using precision flush cutters.
Page 46
Figure 50. Removing the SUM lid
Figure
Drain Wire(s) inserted and secured
Confidential – Limited Distribution
51. Close the