Figure 82. Status check using the Status tab in the Web User Interface (WUI)
Items to note are Voltage, Current, Uptime, ChanA, and ChanB Cable Fault.
Performance Testing – Every 180 Days:
Performance testing is a must for maintaining an alarm system that consistently performs at
a high level over time. At regular intervals, each sensor cable length should be tested to
verify that it captures intrusions and that the respective intrusions are being annunciated at
the head-end. Test each zone or sector using the basic and/or advanced techniques
described in
Intrusion Testing.
lower Probability of Detection (PD) in the past.
Perform a minimum of 10 test intrusions, 10 test per 100 m (328 ft) of sensor for cable
lengths greater than 100 m (328 ft). The PD should be calculated based on these
performance tests and recorded into a test log.

Maintenance and Test Log:

A written log containing the results of system inspections and intrusion tests will assist in
maintaining accountability for the security team. The maintenance log can help identify
performance trends over time. Systems can be configured based on seasonal trends to
Page 74
Test at random locations to test any spots that have shown