Step 15

Connect lead-in to SMA female onto the board with fingers. These have fine threads, so
care should be taken when beginning to screw connectors on, do not cross-thread. Once
the connector is finger tight, use the 5/16 in (8 mm) wrench, turn until the connector is
snug. Once snug, tighten an additional 90 degrees or ¼ clockwise turn approximately.

Step 16

Connect the power wire to the terminal block set to the left of the sensor cable connections.
Left connector is -VDC, right +VDC.
Figure 53. Power connections to the left of the sensor cable connections

Step 17

Page 47
Figure 52. Lead-in cable connection
Confidential – Limited Distribution